WARN00DEU Site Information Form (site log)
     International GNSS Service
     See Instructions at:
       https://files.igs.org/pub/station/general/sitelog_instr.txt


0.   Form

     Prepared by (full name)  : GREF Operator (operator.gref@bkg.bund.de)
     Date Prepared            : 2024-02-15
     Report Type              : UPDATE
     If Update:
      Previous Site Log       : warn00deu_20230703.log
      Modified/Added Sections : 3.16, 3.17, 8.1.4, 8.1.2, 8.1.1, 8.1.3, 8.2.2,
                              : 8.2.1, 8.3.4, 8.3.2, 8.3.1, 8.3.3


1.   Site Identification of the GNSS Monument

     Site Name                : Warnemuende
     Four Character ID        : WARN
     Monument Inscription     : 
     IERS DOMES Number        : 14277M002
     CDP Number               : (A4)
     Monument Description     : STEEL MAST
       Height of the Monument : 3.6 m
       Monument Foundation    : STEEL MAST ANCHORED TO THE ROOF
       Foundation Depth       : (m)
     Marker Description       : SURVEY MARKER BOLT ON A STEEL MAST
     Date Installed           : 2003-02-11T12:00Z
     Geologic Characteristic  : (BEDROCK/CLAY/CONGLOMERATE/GRAVEL/SAND/etc)
       Bedrock Type           : (IGNEOUS/METAMORPHIC/SEDIMENTARY)
       Bedrock Condition      : (FRESH/JOINTED/WEATHERED)
       Fracture Spacing       : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm)
       Fault zones nearby     : (YES/NO/Name of the zone)
         Distance/activity    : (multiple lines)
     Additional Information   : Survey Marker Bolt on a steel mast,
                              : fastened on the roof
                              : of the building for the branch office
                              : of the Wasser- und Schifffahrtsamt
                              : in Warnemuende. The Survey Marker Bolt
                              : is 1.2 m above the roof and 9,65 m
                              : above the ground.


2.   Site Location Information

     City or Town             : Rostock-Warnemuende
     State or Province        : Mecklenburg-Vorpommern
     Country                  : Germany
     Tectonic Plate           : EURASIAN
     Approximate Position (ITRF)
       X coordinate (m)       : 3658785.600
       Y coordinate (m)       : 784471.100
       Z coordinate (m)       : 5147870.700
       Latitude (N is +)      : +541011.24
       Longitude (E is +)     : +0120605.14
       Elevation (m,ellips.)  : 50.7
     Additional Information   : (multiple lines)


3.   GNSS Receiver Information

3.1  Receiver Type            : JPS LEGACY
     Satellite System         : GPS+GLO
     Serial Number            : AF2ETZ85Y4G
     Firmware Version         : E_GGD_2/2.2
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2003-02-11T12:00Z
     Date Removed             : 2003-12-05T10:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : Additional Number LE 5800 on the type level

3.2  Receiver Type            : JPS LEGACY
     Satellite System         : GPS+GLO
     Serial Number            : AF2ETZ85Y4G
     Firmware Version         : E_GGD_2/2.3p3
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2003-12-05T10:00Z
     Date Removed             : 2006-03-29T08:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : Additional Number LE 5800 on the type level

3.3  Receiver Type            : JPS LEGACY
     Satellite System         : GPS+GLO
     Serial Number            : AF2ETZ85Y4G
     Firmware Version         : E_GGD_2/2.5p1
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2006-03-29T08:00Z
     Date Removed             : 2007-05-08T11:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : Additional Number LE 5800 on the type level

3.4  Receiver Type            : JPS LEGACY
     Satellite System         : GPS+GLO
     Serial Number            : AF2ETZ85Y4G
     Firmware Version         : 2.6.0 APR,18,2007
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2007-05-08T11:00Z
     Date Removed             : 2008-01-25T11:45Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : Additional Number LE 5800 on the type level

3.5  Receiver Type            : JPS LEGACY
     Satellite System         : GPS+GLO
     Serial Number            : AF2ETZ85Y4G
     Firmware Version         : 2.6.1 JAN,10,2008
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2008-01-25T11:45Z
     Date Removed             : 2015-07-07T08:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : Additional Number LE 5800 on the type level

3.6  Receiver Type            : JAVAD TRE_G3TH DELTA
     Satellite System         : GPS+GLO+GAL+BDS+SBAS
     Serial Number            : 01591
     Firmware Version         : 3.5.9 APR,21,2015
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2015-07-07T09:00Z
     Date Removed             : 2016-07-10T12:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : Bord ID
                              : 013NBW6VQSP3X11CYHBZ506632

3.7  Receiver Type            : JAVAD TRE_G3TH DELTA
     Satellite System         : GPS+GLO+GAL+BDS+SBAS
     Serial Number            : 01591
     Firmware Version         : 3.6.6 APR,27,2016
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2016-07-10T12:00Z
     Date Removed             : 2017-03-28T08:00Z
     Temperature Stabiliz.    : none
     Additional Information   : Bord ID
                              : 013NBW6VQSP3X11CYHBZ506632

3.8  Receiver Type            : JAVAD TRE_G3TH DELTA
     Satellite System         : GPS+GLO+GAL+BDS+SBAS
     Serial Number            : 01591
     Firmware Version         : 3.7.0 MAR,03,2017
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2017-03-28T08:00Z
     Date Removed             : 2017-06-07T09:00Z
     Temperature Stabiliz.    : none
     Additional Information   : Bord ID
                              : 013NBW6VQSP3X11CYHBZ506632

3.9  Receiver Type            : JAVAD TRE_G3TH DELTA
     Satellite System         : GPS+GLO+GAL+BDS+SBAS
     Serial Number            : 01591
     Firmware Version         : 3.7.1 APR,04,2017
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2017-06-07T09:00Z
     Date Removed             : 2019-01-30T09:10Z
     Temperature Stabiliz.    : none
     Additional Information   : Bord ID
                              : 013NBW6VQSP3X11CYHBZ506632

3.10 Receiver Type            : JAVAD TRE_G3TH DELTA
     Satellite System         : GPS+GLO+GAL+BDS+SBAS
     Serial Number            : 01591
     Firmware Version         : 3.7.5P1 JAN,23,2019
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2019-01-30T09:10Z
     Date Removed             : 2019-05-13T11:00Z
     Temperature Stabiliz.    : none
     Additional Information   : Bord ID: 013NBW6VQSP3X11CYHBZ506632

3.11 Receiver Type            : JAVAD TRE_3 DELTA
     Satellite System         : GPS+GLO+GAL+BDS+SBAS
     Serial Number            : 02890
     Firmware Version         : 3.7.6 APR,08,2019
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2019-05-13T11:00Z
     Date Removed             : 2020-03-11T11:00Z
     Temperature Stabiliz.    : none
     Additional Information   : Bord ID: 198GILL1QGDGX0QDSPVJA2QGHS

3.12 Receiver Type            : JAVAD TRE_3 DELTA
     Satellite System         : GPS+GLO+GAL+BDS+SBAS
     Serial Number            : 02890
     Firmware Version         : 3.7.9 DEC,30,2019
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2020-03-11T11:10Z
     Date Removed             : 2020-11-03T14:15Z
     Temperature Stabiliz.    : none
     Additional Information   : Bord ID: 198GILL1QGDGX0QDSPVJA2QGHS

3.13 Receiver Type            : JAVAD TRE_3 DELTA
     Satellite System         : GPS+GLO+GAL+BDS+SBAS
     Serial Number            : 02890
     Firmware Version         : 3.7.10 Oct,22,2020
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2020-11-03T14:15Z
     Date Removed             : 2021-08-31T11:35Z
     Temperature Stabiliz.    : none
     Additional Information   : Bord ID: 198GILL1QGDGX0QDSPVJA2QGHS

3.14 Receiver Type            : JAVAD TRE_3 DELTA
     Satellite System         : GPS+GLO+GAL+BDS+SBAS
     Serial Number            : 02890
     Firmware Version         : 4.1.03-210713
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2021-08-31T11:35Z
     Date Removed             : 2022-03-03T07:20Z
     Temperature Stabiliz.    : none
     Additional Information   : Bord ID: 198GILL1QGDGX0QDSPVJA2QGHS

3.15 Receiver Type            : JAVAD TRE_3 DELTA
     Satellite System         : GPS+GLO+GAL+BDS+SBAS
     Serial Number            : 02890
     Firmware Version         : 4.1.04-211206
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2022-03-03T07:20Z
     Date Removed             : 2023-02-08T09:59Z
     Temperature Stabiliz.    : none
     Additional Information   : Bord ID: 198GILL1QGDGX0QDSPVJA2QGHS

3.16 Receiver Type            : JAVAD TRE_3 DELTA
     Satellite System         : GPS+GLO+GAL+BDS+SBAS
     Serial Number            : 02890
     Firmware Version         : 4.1.06-221128
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2023-02-08T09:59Z
     Date Removed             : 2024-02-15T09:49Z
     Temperature Stabiliz.    : none
     Additional Information   : Bord ID: 198GILL1QGDGX0QDSPVJA2QGHS

3.17 Receiver Type            : JAVAD TRE_3 DELTA
     Satellite System         : GPS+GLO+GAL+BDS+SBAS
     Serial Number            : 02890
     Firmware Version         : 4.3.00-231129
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2024-02-15T09:49Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Temperature Stabiliz.    : none
     Additional Information   : Bord ID: 198GILL1QGDGX0QDSPVJA2QGHS

3.x  Receiver Type            : (A20, from rcvr_ant.tab; see instructions)
     Satellite System         : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS)
     Serial Number            : (A20, but note the first A5 is used in SINEX)
     Firmware Version         : (A11)
     Elevation Cutoff Setting : (deg)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Temperature Stabiliz.    : (none or tolerance in degrees C)
     Additional Information   : (multiple lines)


4.   GNSS Antenna Information

4.1  Antenna Type             : TPSCR3_GGD      CONE
     Serial Number            : 217 0111
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.1750
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : CONE
     Radome Serial Number     : 
     Antenna Cable Type       : Aircom plus
     Antenna Cable Length     : 50 m
     Date Installed           : 2003-02-11T12:00Z
     Date Removed             : 2003-10-22T08:00Z
     Additional Information   : (multiple lines)

4.2  Antenna Type             : TPSCR3_GGD      CONE
     Serial Number            : 217 0159
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.1750
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : CONE
     Radome Serial Number     : 
     Antenna Cable Type       : Aircom plus
     Antenna Cable Length     : 50 m
     Date Installed           : 2003-10-22T08:00Z
     Date Removed             : 2004-08-12T08:00Z
     Additional Information   : absolute Individuel Calibration

4.3  Antenna Type             : TPSCR3_GGD      CONE
     Serial Number            : 217 0159
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.0686
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : CONE
     Radome Serial Number     : 
     Antenna Cable Type       : Aircom plus
     Antenna Cable Length     : 50 m
     Date Installed           : 2004-08-12T08:00Z
     Date Removed             : 2005-03-01T05:00Z
     Additional Information   : absolute Individuel Calibration

4.4  Antenna Type             : TPSCR3_GGD      CONE
     Serial Number            : 217 0159
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.0690
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : CONE
     Radome Serial Number     : 
     Antenna Cable Type       : Aircom plus
     Antenna Cable Length     : 50 m
     Date Installed           : 2005-03-01T05:00Z
     Date Removed             : 2010-09-15T09:00Z
     Additional Information   : absolute Individuel Calibration

4.5  Antenna Type             : LEIAR25.R3      LEIT
     Serial Number            : 09050002
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.0690
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : LEIT
     Radome Serial Number     : 
     Antenna Cable Type       : RG214
     Antenna Cable Length     : 20 m
     Date Installed           : 2010-09-15T09:30Z
     Date Removed             : 2019-05-13T11:00Z
     Additional Information   : Antenna calibrated absolute
                              : by Geo++ GmbH, Garbsen 2010-07-01.

4.6  Antenna Type             : LEIAR25.R4      LEIT
     Serial Number            : 725559
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.0690
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : LEIT
     Radome Serial Number     : 
     Antenna Cable Type       : RG214
     Antenna Cable Length     : 20 m
     Date Installed           : 2019-05-13T11:00Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Additional Information   : Antenna individual calibrated absolutely by
                              : : GEO++ - ROBOT 2013-01-10
                              : : UNI BONN - CHAMBER 2013-03-12
                              : : UNI BONN - CHAMBER 2018-10-15
                              : : Senatsverwaltung Berlin - ROBOT 2019-05-02

4.x  Antenna Type             : (A20, from rcvr_ant.tab; see instructions)
     Serial Number            : (A*, but note the first A5 is used in SINEX)
     Antenna Reference Point  : (BPA/BCR/XXX from "antenna.gra"; see instr.)
     Marker->ARP Up Ecc. (m)  : (F8.4)
     Marker->ARP North Ecc(m) : (F8.4)
     Marker->ARP East Ecc(m)  : (F8.4)
     Alignment from True N    : (deg; + is clockwise/east)
     Antenna Radome Type      : (A4 from rcvr_ant.tab; see instructions)
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : (m)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


5.   Surveyed Local Ties

5.x  Tied Marker Name         : 
     Tied Marker Usage        : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : (m)
       dy (m)                 : (m)
       dz (m)                 : (m)
     Accuracy (mm)            : (mm)
     Survey method            : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc)
     Date Measured            : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


6.   Frequency Standard

6.1  Standard Type            : INTERNAL
       Input Frequency        : (if external)
       Effective Dates        : 2003-02-11/CCYY-MM-DD
       Notes                  : (multiple lines)

6.x  Standard Type            : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc)
       Input Frequency        : (if external)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


7.   Collocation Information

7.1  Instrumentation Type     : GNSS WARN01DEU
       Status                 : PERMANENT
       Effective Dates        : 2016-07-26/CCYY-MM-DD
       Notes                  : Secondary Receiver at the same antenna.
                              : More information and data available on
                              : request.

7.x  Instrumentation Type     : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc)
       Status                 : (PERMANENT/MOBILE)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


8.   Meteorological Instrumentation

8.1.1  Humidity Sensor Model  : HMP45A-P
       Manufacturer           : Vaisala Oyi
       Serial Number          : X2930002
       Data Sampling Interval :   900 sec
       Accuracy (% rel h)     : 1 % rel h
       Aspiration             : CAPACITIVY THIN FILM POLYMER
       Height Diff to Ant     : 0.13 m
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : 2003-02-11/2010-09-15
       Notes                  : The humidity sensor is 0.13 m
                              : below the antenna.

8.1.2  Humidity Sensor Model  : HMP45A-P
       Manufacturer           : Vaisala Oyi
       Serial Number          : X4150004
       Data Sampling Interval :    10 sec
       Accuracy (% rel h)     : 1 % rel h
       Aspiration             : CAPACITIVY THIN FILM POLYMER
       Height Diff to Ant     : -0.15 m
       Calibration date       : 2009-08-12
       Effective Dates        : 2010-09-15/2017-03-28
       Notes                  : The humidity sensor is 0.15 m
                              : below the antenna.

8.1.3  Humidity Sensor Model  : HMP45A-P
       Manufacturer           : Vaisala
       Serial Number          : X4150003
       Data Sampling Interval :    10 sec
       Accuracy (% rel h)     : 1 % rel h
       Aspiration             : CAPACITIVY THIN FILM POLYMER
       Height Diff to Ant     : -0.15 m
       Calibration date       : 2015-11-23
       Effective Dates        : 2017-03-28/2023-05-23
       Notes                  : The humidity sensor is 0.15 m
                              : below the antenna.

8.1.4  Humidity Sensor Model  : WXTPTU
       Manufacturer           : Vaisala
       Serial Number          : U4430139
       Data Sampling Interval :    10 sec
       Accuracy (% rel h)     : 3 % rel h
       Aspiration             : NATURAL
       Height Diff to Ant     : 0 m
       Calibration date       : 2023-01-03
       Effective Dates        : 2023-05-24/CCYY-MM-DD
       Notes                  : Vaisala WXT530 SN: P3710986
                              : Humidity Sensor is 0.2 m below the antenna
                              : capacitive thin film polymer HUMICAP 180 sensor

8.1.x  Humidity Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.2.1  Pressure Sensor Model  : PTU200
       Manufacturer           : Vaisala
       Serial Number          : X2930002
       Data Sampling Interval :  10 sec
       Accuracy               : 0.1 hPa
       Height Diff to Ant     : -3.8 m
       Calibration date       : 2002-07-22
       Effective Dates        : 2003-02-11/2023-05-23
       Notes                  : The pressure Sensor is
                              : 3.8 m below the antenna.

8.2.2  Pressure Sensor Model  : WXTPTU
       Manufacturer           : Vaisala
       Serial Number          : U4430139
       Data Sampling Interval :  10 sec
       Accuracy               : 1 hPa
       Height Diff to Ant     : 0 m
       Calibration date       : 2023-01-03
       Effective Dates        : 2023-05-24/CCYY-MM-DD
       Notes                  : Vaisala WXT530 SN: P3710986
                              : Pressure Sensor is 0.2 m below the antenna
                              : capacitive silicon BAROCAP sensor

8.2.x  Pressure Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (hPa)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.3.1  Temp. Sensor Model     : HMP45A-P
       Manufacturer           : Vaisala Oyi
       Serial Number          : X2930002
       Data Sampling Interval : 10 sec
       Accuracy               : 0.2 deg C
       Aspiration             : RESISTIVE PLATINUM PROBE
       Height Diff to Ant     : 0.13 m
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : 2003-02-11/2010-09-15
       Notes                  : The temperature sensor is
                              : 0.13 m below the antenna.

8.3.2  Temp. Sensor Model     : HMP45A-P
       Manufacturer           : Vaisala Oyi
       Serial Number          : X4150004
       Data Sampling Interval : 10 sec
       Accuracy               : 0.2 deg C
       Aspiration             : RESISTIVE PLATINUM PROBE
       Height Diff to Ant     : -0.15 m
       Calibration date       : 2009-08-12
       Effective Dates        : 2010-09-15/2017-03-28
       Notes                  : The temperature sensor is
                              : 0.15 m below the antenna.

8.3.3  Temp. Sensor Model     : HMP45A-P
       Manufacturer           : Vaisala
       Serial Number          : X4150003
       Data Sampling Interval : 10 sec
       Accuracy               : 0.2 deg C
       Aspiration             : RESISTIVE PLATINUM PROBE
       Height Diff to Ant     : -0.15 m
       Calibration date       : 2015-11-23
       Effective Dates        : 2017-03-28/2023-05-23
       Notes                  : The temperature sensor is
                              : 0.15 m below the antenna.

8.3.4  Temp. Sensor Model     : WXTPTU
       Manufacturer           : Vaisala
       Serial Number          : U4430139
       Data Sampling Interval : 10 sec
       Accuracy               : 0.3 deg C
       Aspiration             : NATURAL
       Height Diff to Ant     : 0 m
       Calibration date       : 2023-01-03
       Effective Dates        : 2023-05-24/CCYY-MM-DD
       Notes                  : Vaisala WXT530 SN: P3710986
                              : Temperature Sensor is 0.2 m below the antenna
                              : capacitive ceramic THERMOCAP sensor

8.3.x  Temp. Sensor Model     : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.4.x  Water Vapor Radiometer : 
       Manufacturer           : 
       Serial Number          : 
       Distance to Antenna    : (m)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.5.1  Other Instrumentation  : Wind Azimut
                              : Wind Sensor Model WXT530  (not heated)
                              : Manufacturer Vaisala
                              : Serial Number Wind Sensor U3930979
                              : Data Sampling Interval 10 sec
                              : Accuracy 3 deg
                              : Height Diff to Ant -0.2 m
                              : Test date 2023-01-03
                              : Effective Dates 2023-05-24/CCYY-MM-DD
                              : Vaisala WXT530 SN: P3710986
                              : Notes Wind Sensor is at the height of the
                              : antenna
                              : Notes ultrasonic WINDCAP sensor

8.5.2  Other Instrumentation  : Wind Speed
                              : Wind Sensor Model WXT530 (not heated)
                              : Manufacturer Vaisala
                              : Serial Number Wind Sensor U3930979
                              : Data Sampling Interval 10 sec
                              : Accuracy
                              : measurement values 0..35 m/s  0.3 m/s or 3%
                              : measurement values 36..60 m/s  5%
                              : Height Diff to Ant -0.2 m
                              : Test date 2023-01-03
                              : Effective Dates 2023-05-24/CCYY-MM-DD
                              : Vaisala WXT530 SN: P3710986
                              : Notes Wind Sensor is at the height of the
                              : antenna
                              : Notes ultrasonic WINDCAP sensor

8.5.3  Other Instrumentation  : Rain Increment
                              : Rain Sensor Model WXT530 (heated)
                              : Manufacturer Vaisala
                              : Serial Number Rain Sensor U3930979
                              : Data Sampling Interval 10 sec
                              : Accuracy 5 %
                              : Height Diff to Ant -0.2 m
                              : Test date 2023-01-03
                              : Effective Dates 2023-05-24/CCYY-MM-DD
                              : Vaisala WXT530 SN: P3710986
                              : Notes Rain Sensor is at the height of the
                              : antenna
                              : Notes piezoelectrical RAINCAP sensor

8.5.4  Other Instrumentation  : Hail Indicator
                              : Hail Sensor Model WXT530 (not heated)
                              : Manufacturer Vaisala
                              : Serial Number Hail Sensor U3930979
                              : Data Sampling Interval 10 sec
                              : Accuracy 5 %
                              : Height Diff to Ant -0.2 m
                              : Test date 2023-01-03
                              : Effective Dates 2023-05-24/CCYY-MM-DD
                              : Vaisala WXT530 SN: P3710986
                              : Notes Hail Sensor is at the height of the
                              : antenna
                              : Notes piezoelectrical RAINCAP sensor

8.5.x  Other Instrumentation  : (multiple lines)


9.   Local Ongoing Conditions Possibly Affecting Computed Position

9.1.x  Radio Interferences    : (TV/CELL PHONE ANTENNA/RADAR/etc)
       Observed Degradations  : (SN RATIO/DATA GAPS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.2.x  Multipath Sources      : (METAL ROOF/DOME/VLBI ANTENNA/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.3.x  Signal Obstructions    : (TREES/BUILDINGS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)


10.  Local Episodic Effects Possibly Affecting Data Quality

10.x  Date                    : (CCYY-MM-DD/CCYY-MM-DD)
      Event                   : (TREE CLEARING/CONSTRUCTION/etc)


11.  On-Site, Point of Contact Agency Information

     Agency                   : Bundesamt fuer Kartographie und Geodaesie
                              : Department of Geodaesie
     Preferred Abbreviation   : BKG
     Mailing Address          : Richard-Strauss-Allee 11
                              : D-60598 Frankfurt a.M.
                              : Germany
     Primary Contact
       Contact Name           : GREF Operator
       Telephone (primary)    : +49 341 5634410
       Telephone (secondary)  : +49 341 5634432
       Fax                    : +49 341 5634415
       E-mail                 : operator.gref@bkg.bund.de
     Secondary Contact
       Contact Name           : BKG GNSS Data Center
       Telephone (primary)    : +49 69 6333274
       Telephone (secondary)  : +49 69 63331
       Fax                    : +49 69 6333425
       E-mail                 : bkg-gdc@bkg.bund.de
     Additional Information   : (multiple lines)




12.  Responsible Agency (if different from 11.)

     Agency                   : (multiple lines)
     Preferred Abbreviation   : (A10)
     Mailing Address          : (multiple lines)
     Primary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : (multiple lines)


13.  More Information

     Primary Data Center      : BKG
     Secondary Data Center    : BEV
     URL for More Information : https://gref.bkg.bund.de
     Hardcopy on File
       Site Map               : (Y or URL)
       Site Diagram           : (Y or URL)
       Horizon Mask           : (Y or URL)
       Monument Description   : (Y or URL)
       Site Pictures          : Y
     Additional Information   : (multiple lines)
     Antenna Graphics with Dimensions

Topcon Positioning Systems: TPSCR3_GGD

                          ---------
                        /     +     \                        <-- 0.104 L2
                       |      +      |                       <-- 0.081 L1
     +--------------------------------------------------+    <-- 0.071 TCR
     |                                                  |
     |                                                  |
     |                                                  |
     |                                                  |
     +-----------------+-------------+------------------+    <-- 0.003 BCR
                        +-----x-----+                        <-- 0.0 BPA=ARP
                            +---+
                            |   |
                            |   |
                            |   |
                            |   |
                            |   |
                            |   |
	                        +---+
                  +---------+---+----------+                 <-- -0.0686

     <--                    0.326                     -->

LEIAR25.R3

                         /         \
                          +-------+                          <--  0.1995
                   +---+-------------+---+                   <--  0.1606  TCR
                   |                     |
                |---------------------------|
             |---------------------------------|
          |---------------------------------------|
       +---------------------------------------------+
       |                                             |
       |                                             |
     +-+---------------------------------------------+-+
     +-----------------+-------------+-----------------+     <--  0.0320  BCR
                       |             |
                       |             |
                       +------x------+                       <--  0.0000  BPA=ARP
					   
     <--                    0.3802                   -->
	 
LEIAR25.R4

                          +-------+                          <--  0.1995
                         /         \
                   +---+-------------+---+                   <--  0.1606  TCR
                   |                     |
                |---------------------------|
             |---------------------------------|
          |---------------------------------------|
       +---------------------------------------------+
       |                                             |
       |                                             |
     +-+---------------------------------------------+-+
     +-----------------+-------------+-----------------+     <--  0.0320  BCR
                       |             |
                       |             |
                       +------x------+                       <--  0.0000  BPA=ARP
					   
     <--                    0.3802                   -->

   ARP: Antenna Reference Point
   L1 : L1 Phase Center                   L2 : L2 Phase Center
   TCR: Top of Chokering                  BCR: Bottom of Chokering
   TGP: Top of Ground Plane               BGP: Bottom of Ground Plane
   TPA: Top of Preamplifier               BPA: Bottom of Preamplifier
   TOP: Top of Pole                       BOP: Bottom of Pole

All dimensions are in meters.