******************************************************************************* EUREF Electronic Mail 10-Sep-2019 06:30:06 UTC Message Number 09971 ******************************************************************************* Author: EPN CB/C.Bruyninx Subject: Recalibration of antenna presently at FFMJ00DEU Dear Colleagues, We would like to inform you that we received a new chamber calibration (calibration date July 2019) for the antenna LEIAR25.R3/LEIT (SN 09050002), installed at: - WARN00DEU, from 2010-09-15 to 2019-05-13 (included in the EPN analysis with old indiv. robot calibrations) - FFMJ00DEU, from 2019-09-04 In order to introduce the new chamber calibration, we removed temporarily the old robot calibration of the LEIAR25.R3/LEIT (SN 09050002) from the EPN antenna calibration files epnc_14.atx and epn_14.atx. Users who wish to reprocess data of the station WARN00DEU (from 2010-09-15 to 2019-05-13) and get results completely consistent with the operational EPN analysis during that period, must use the old robot calibration which is available from: ftp://epncb.eu/pub/station/general/indiv_calibrations/LEIAR25.R3-LEIT-50002-GEO-20100701-WARN.atx Best regards, Carine Bruyninx EPN Central Bureau [Mailed from: md ] EUREF Mailing list maintained by epncb@oma.be and archived at ftp://epncb.oma.be/epncb/mail/ and http://epncb.oma.be/_newseventslinks/EUREFmail/